Ordering no:
Male angled connector, cable outlet 6-8 mm, metal model
Male angled connector, cable outlet 6-8 mm, metal model, Series 682
Available numbers of contacts
Variants for number of contacts 2
Variants for number of contacts 3
Variants for number of contacts 4
Variants for number of contacts 5
Variants for number of contacts 6
Variants for number of contacts 7
Variants for number of contacts 8
Variants for number of contacts 12
Variants for number of contacts 14
Variants for number of contacts 19
Variants for number of contacts 24
99 0133 12 02
M16 IP40 male angled connector, Contacts: 2, 6,0 - 8,0 mm, shieldable, solder, IP40
M16, series 682, Miniature connectors
Order number |
99 0133 12 02
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0,75 mm² |
Wire gauge (AWG) | 20 |
Cable outlet | 6,0 - 8,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 7 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 34.271 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
99 0135 12 03
M16 IP40 male angled connector, Contacts: 3, 6,0 - 8,0 mm, shieldable, solder, IP40
M16, series 682, Miniature connectors
Order number |
99 0135 12 03
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0,75 mm² |
Wire gauge (AWG) | 20 |
Cable outlet | 6,0 - 8,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 7 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 34.5 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
99 0137 12 04
M16 IP40 male angled connector, Contacts: 4, 6,0 - 8,0 mm, shieldable, solder, IP40
M16, series 682, Miniature connectors
Order number |
99 0137 12 04
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0,75 mm² |
Wire gauge (AWG) | 20 |
Cable outlet | 6,0 - 8,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 6 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 34.711 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
99 0141 12 05
M16 IP40 male angled connector, Contacts: 5, 6,0 - 8,0 mm, shieldable, solder, IP40
M16, series 682, Miniature connectors
Order number |
99 0141 12 05
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0,75 mm² |
Wire gauge (AWG) | 20 |
Cable outlet | 6,0 - 8,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 6 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 34.953 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
99 0143 12 06
M16 IP40 male angled connector, Contacts: 6, 6,0 - 8,0 mm, shieldable, solder, IP40
M16, series 682, Miniature connectors
Order number |
99 0143 12 06
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0,75 mm² |
Wire gauge (AWG) | 20 |
Cable outlet | 6,0 - 8,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 5 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 35.171 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
99 0145 12 07
M16 IP40 male angled connector, Contacts: 7, 6,0 - 8,0 mm, shieldable, solder, IP40
M16, series 682, Miniature connectors
Order number |
99 0145 12 07
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0,75 mm² |
Wire gauge (AWG) | 20 |
Cable outlet | 6,0 - 8,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 5 A |
Rated voltage | 125 V |
Rated impulse voltage | 800 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 35.457 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
99 0153 12 08
M16 IP40 male angled connector, Contacts: 8, 6,0 - 8,0 mm, shieldable, solder, IP40
M16, series 682, Miniature connectors
Order number |
99 0153 12 08
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0,75 mm² |
Wire gauge (AWG) | 20 |
Cable outlet | 6,0 - 8,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 5 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 35.652 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
99 0147 12 12
M16 IP40 male angled connector, Contacts: 12, 6,0 - 8,0 mm, shieldable, solder, IP40
M16, series 682, Miniature connectors
Order number |
99 0147 12 12
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0,25 mm² |
Wire gauge (AWG) | 24 |
Cable outlet | 6,0 - 8,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 3 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 34.895 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
99 0161 12 14
M16 IP40 male angled connector, Contacts: 14, 6,0 - 8,0 mm, shieldable, solder, IP40
M16, series 682, Miniature connectors
Order number |
99 0161 12 14
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0,25 mm² |
Wire gauge (AWG) | 24 |
Cable outlet | 6,0 - 8,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 3 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 35.056 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
99 0163 12 19
M16 IP40 male angled connector, Contacts: 19, 6,0 - 8,0 mm, shieldable, solder, IP40
M16, series 682, Miniature connectors
Order number |
99 0163 12 19
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0,25 mm² |
Wire gauge (AWG) | 24 |
Cable outlet | 6,0 - 8,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 3 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 35.532 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
99 0165 12 24
M16 IP40 male angled connector, Contacts: 24, 6,0 - 8,0 mm, shieldable, solder, IP40
M16, series 682, Miniature connectors
Order number |
99 0165 12 24
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0,14 mm² |
Wire gauge (AWG) | 26 |
Cable outlet | 6,0 - 8,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 1 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 34.99 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Contact to customer service