Ordering no:
Male panel mount connector, solder, screwed from front, UL approval
Male panel mount connector, solder, screwed from front, UL approval, Series 423/ 723/ 425
Available numbers of contacts
09 0103 80 02
M16 IP67 male panel mount connector, Contacts: 2, Shielding is not possible, solder, IP67, UL
M16, series 723, Miniature connectors
Order number |
09 0103 80 02
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 95 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 7 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Housing material | Zinc die-cast nickel-plated |
Approval 1 | UL |
Customs tariff number | 85369010 |
Weight (g) | 11.132 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
Downloads
Data sheet
Certificates
CAD files
09 0103 89 02
M16 IP67 male panel mount connector, Contacts: 2, Shielding is not possible, solder, IP67, UL
M16, series 723, Miniature connectors
Order number |
09 0103 89 02
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 95 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 7 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | Zinc die-cast nickel-plated |
Approval 1 | UL |
Customs tariff number | 85369010 |
Weight (g) | 11.141 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
Downloads
Data sheet
Certificates
CAD files
09 0107 80 03
M16 IP67 male panel mount connector, Contacts: 3 DIN, Shielding is not possible, solder, IP67, UL
M16, series 723, Miniature connectors
Order number |
09 0107 80 03
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 95 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 7 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Housing material | Zinc die-cast nickel-plated |
Approval 1 | UL |
Customs tariff number | 85369010 |
Weight (g) | 11.373 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
Downloads
Data sheet
Certificates
CAD files
09 0107 89 03
M16 IP67 male panel mount connector, Contacts: 3 DIN, Shielding is not possible, solder, IP67, UL
M16, series 723, Miniature connectors
Order number |
09 0107 89 03
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 95 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 7 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | Zinc die-cast nickel-plated |
Approval 1 | UL |
Customs tariff number | 85369010 |
Weight (g) | 11.379 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
Downloads
Data sheet
Certificates
CAD files
09 0111 80 04
M16 IP67 male panel mount connector, Contacts: 4, shielded, solder, IP67, UL
M16, series 723, Miniature connectors
Order number |
09 0111 80 04
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 95 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 6 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Housing material | Zinc die-cast nickel-plated |
Approval 1 | UL |
Customs tariff number | 85369010 |
Weight (g) | 11.611 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
Downloads
Data sheet
Certificates
CAD files
09 0111 89 04
M16 IP67 male panel mount connector, Contacts: 4, Shielding is not possible, solder, IP67, UL
M16, series 723, Miniature connectors
Order number |
09 0111 89 04
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 95 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 6 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | Zinc die-cast nickel-plated |
Approval 1 | UL |
Customs tariff number | 85369010 |
Weight (g) | 11.591 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
Downloads
Data sheet
Certificates
CAD files
09 0115 80 05
M16 IP67 male panel mount connector, Contacts: 5, Shielding is not possible, solder, IP67, UL
M16, series 723, Miniature connectors
Order number |
09 0115 80 05
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 95 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 6 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Housing material | Zinc die-cast nickel-plated |
Approval 1 | UL |
Customs tariff number | 85369010 |
Weight (g) | 11.622 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
Downloads
Data sheet
Certificates
CAD files
09 0115 89 05
M16 IP67 male panel mount connector, Contacts: 5, Shielding is not possible, solder, IP67, UL
M16, series 723, Miniature connectors
Order number |
09 0115 89 05
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 95 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 6 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | Zinc die-cast nickel-plated |
Approval 1 | UL |
Customs tariff number | 85369010 |
Weight (g) | 11.622 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
Downloads
Data sheet
Certificates
CAD files
09 0119 80 05
M16 IP67 male panel mount connector, Contacts: 5 (stereo), Shielding is not possible, solder, IP67, UL
M16, series 723, Miniature connectors
Order number |
09 0119 80 05
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 95 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 6 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Housing material | Zinc die-cast nickel-plated |
Approval 1 | UL |
Customs tariff number | 85369010 |
Weight (g) | 11.825 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
Downloads
Data sheet
Certificates
CAD files
09 0119 89 05
M16 IP67 male panel mount connector, Contacts: 5 (stereo), Shielding is not possible, solder, IP67, UL
M16, series 723, Miniature connectors
Order number |
09 0119 89 05
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 95 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 6 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | Zinc die-cast nickel-plated |
Approval 1 | UL |
Customs tariff number | 85369010 |
Weight (g) | 11.839 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
Downloads
Data sheet
Certificates
CAD files
09 0123 80 06
M16 IP67 male panel mount connector, Contacts: 6 DIN, Shielding is not possible, solder, IP67, UL
M16, series 723, Miniature connectors
Order number |
09 0123 80 06
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 95 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 5 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Housing material | Zinc die-cast nickel-plated |
Approval 1 | UL |
Customs tariff number | 85369010 |
Weight (g) | 12.072 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
Downloads
Data sheet
Certificates
CAD files
09 0123 89 06
M16 IP67 male panel mount connector, Contacts: 6 DIN, Shielding is not possible, solder, IP67, UL
M16, series 723, Miniature connectors
Order number |
09 0123 89 06
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 95 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 5 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | Zinc die-cast nickel-plated |
Approval 1 | UL |
Customs tariff number | 85369010 |
Weight (g) | 12.08 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
Downloads
Data sheet
Certificates
CAD files
09 0127 80 07
M16 IP67 male panel mount connector, Contacts: 7, Shielding is not possible, solder, IP67, UL
M16, series 723, Miniature connectors
Order number |
09 0127 80 07
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 95 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 5 A |
Rated voltage | 125 V |
Rated impulse voltage | 800 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Housing material | Zinc die-cast nickel-plated |
Approval 1 | UL |
Customs tariff number | 85369010 |
Weight (g) | 12.303 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
Downloads
Data sheet
Certificates
CAD files
09 0127 89 07
M16 IP67 male panel mount connector, Contacts: 7, Shielding is not possible, solder, IP67, UL
M16, series 723, Miniature connectors
Order number |
09 0127 89 07
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 95 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 5 A |
Rated voltage | 125 V |
Rated impulse voltage | 800 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | Zinc die-cast nickel-plated |
Approval 1 | UL |
Customs tariff number | 85369010 |
Weight (g) | 12.295 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
Downloads
Data sheet
Certificates
CAD files
09 0173 80 08
M16 IP67 male panel mount connector, Contacts: 8 DIN, Shielding is not possible, solder, IP67, UL
M16, series 723, Miniature connectors
Order number |
09 0173 80 08
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 95 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 5 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Housing material | Zinc die-cast nickel-plated |
Approval 1 | UL |
Customs tariff number | 85369010 |
Weight (g) | 12.529 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
Downloads
Data sheet
Certificates
CAD files
09 0173 89 08
M16 IP67 male panel mount connector, Contacts: 8 DIN, Shielding is not possible, solder, IP67, UL
M16, series 723, Miniature connectors
Order number |
09 0173 89 08
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 95 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 5 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | Zinc die-cast nickel-plated |
Approval 1 | UL |
Customs tariff number | 85369010 |
Weight (g) | 12.525 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
Downloads
Data sheet
Certificates
CAD files
09 0131 80 12
M16 IP67 male panel mount connector, Contacts: 12, Shielding is not possible, solder, IP67, UL
M16, series 723, Miniature connectors
Order number |
09 0131 80 12
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.25 mm² |
Wire gauge (AWG) | 24 |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 95 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 3 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | Zinc die-cast nickel-plated |
Approval 1 | UL |
Customs tariff number | 85369010 |
Weight (g) | 11.99 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
Downloads
Data sheet
Certificates
CAD files
09 0453 80 14
M16 IP67 male panel mount connector, Contacts: 14, Shielding is not possible, solder, IP67, UL
M16, series 723, Miniature connectors
Order number |
09 0453 80 14
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.25 mm² |
Wire gauge (AWG) | 24 |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 95 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 3 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | Zinc die-cast nickel-plated |
Approval 1 | UL |
Customs tariff number | 85369010 |
Weight (g) | 12.208 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
Downloads
Data sheet
Certificates
CAD files
09 0507 80 16
M16 IP67 male panel mount connector, Contacts: 16, Shielding is not possible, solder, IP67, UL
M16, series 723, Miniature connectors
Order number |
09 0507 80 16
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.25 mm² |
Wire gauge (AWG) | 24 |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 95 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 3 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | Zinc die-cast nickel-plated |
Approval 1 | UL |
Customs tariff number | 85369010 |
Weight (g) | 12.427 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
Downloads
Data sheet
Certificates
CAD files
09 0463 80 19
M16 IP67 male panel mount connector, Contacts: 19, Shielding is not possible, solder, IP67, UL
M16, series 723, Miniature connectors
Order number |
09 0463 80 19
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.25 mm² |
Wire gauge (AWG) | 24 |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 95 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 3 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | Zinc die-cast nickel-plated |
Approval 1 | UL |
Customs tariff number | 85369010 |
Weight (g) | 12.756 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
Downloads
Data sheet
Certificates
CAD files
09 0497 80 24
M16 IP67 male panel mount connector, Contacts: 24, Shielding is not possible, solder, IP67, UL
M16, series 723, Miniature connectors
Order number |
09 0497 80 24
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.14 mm² |
Wire gauge (AWG) | 26 |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 95 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 1 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | Zinc die-cast nickel-plated |
Approval 1 | UL |
Customs tariff number | 85369010 |
Weight (g) | 12.07 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
Downloads
Data sheet
Certificates
CAD files
Contact to customer service
Do you have any questions regarding our products or do you wish an individual offer?