Available numbers of contacts
09 4808 15 03
Push-Pull female panel mount connector, Contacts: 3 DIN, Shielding is not possible, solder, IP67
Push Pull, series 440, Miniature connectors
Order number |
09 4808 15 03
|
Connector locking system | Push-Pull |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP67 |
Mechanical operation | > 1000 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 7 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 20.474 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
09 4812 15 04
Push-Pull female panel mount connector, Contacts: 4, Shielding is not possible, solder, IP67
Push Pull, series 440, Miniature connectors
Order number |
09 4812 15 04
|
Connector locking system | Push-Pull |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP67 |
Mechanical operation | > 1000 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 6 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 20.657 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
09 4816 15 05
Push-Pull female panel mount connector, Contacts: 5, Shielding is not possible, solder, IP67
Push Pull, series 440, Miniature connectors
Order number |
09 4816 15 05
|
Connector locking system | Push-Pull |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP67 |
Mechanical operation | > 1000 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 6 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 20.751 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
09 4820 15 06
Push-Pull female panel mount connector, Contacts: 6 DIN, Shielding is not possible, solder, IP67
Push Pull, series 440, Miniature connectors
Order number |
09 4820 15 06
|
Connector locking system | Push-Pull |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP67 |
Mechanical operation | > 1000 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 5 A |
Rated voltage | 125 V |
Rated impulse voltage | 800 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 20.957 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
09 4828 15 07
Push-Pull female panel mount connector, Contacts: 7, Shielding is not possible, solder, IP67
Push Pull, series 440, Miniature connectors
Order number |
09 4828 15 07
|
Connector locking system | Push-Pull |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP67 |
Mechanical operation | > 1000 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 5 A |
Rated voltage | 125 V |
Rated impulse voltage | 800 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 21.061 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
09 4832 15 08
Push-Pull female panel mount connector, Contacts: 8 DIN, Shielding is not possible, solder, IP67
Push Pull, series 440, Miniature connectors
Order number |
09 4832 15 08
|
Connector locking system | Push-Pull |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP67 |
Mechanical operation | > 1000 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 5 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 21.913 |





Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
09 4836 15 12
Push-Pull female panel mount connector, Contacts: 12, Shielding is not possible, solder, IP67
Push Pull, series 440, Miniature connectors
Order number |
09 4836 15 12
|
Connector locking system | Push-Pull |
Termination | solder |
Wire gauge (mm) | 0.25 mm² |
Wire gauge (AWG) | 24 |
Degree of protection | IP67 |
Mechanical operation | > 1000 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 3 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 20.543 |





Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
09 4840 15 14
Push-Pull female panel mount connector, Contacts: 14, Shielding is not possible, solder, IP67
Push Pull, series 440, Miniature connectors
Order number |
09 4840 15 14
|
Connector locking system | Push-Pull |
Termination | solder |
Wire gauge (mm) | 0.25 mm² |
Wire gauge (AWG) | 24 |
Degree of protection | IP67 |
Mechanical operation | > 1000 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 3 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 20.661 |





Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
09 4844 15 19
Push-Pull female panel mount connector, Contacts: 19, Shielding is not possible, solder, IP67
Push Pull, series 440, Miniature connectors
Order number |
09 4844 15 19
|
Connector locking system | Push-Pull |
Termination | solder |
Wire gauge (mm) | 0.25 mm² |
Wire gauge (AWG) | 24 |
Degree of protection | IP67 |
Mechanical operation | > 1000 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 3 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 20.942 |





Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
Contact to customer service