Ordering no:
Male cable connector, cable outlet 7-17mm
Male cable connector, cable outlet 7-17mm, Series 692/693
Available numbers of contacts
99 4221 300 04
RD24 cable connector, Contacts: 3+PE, 7,0 - 17,0 mm, Shielding is not possible, screw clamp, IP67, Vario
RD24, series 693, Power connectors
Order number |
99 4221 300 04
|
Connector locking system | bolted |
Termination | screw clamp |
Wire gauge (mm) | max. 2.50 mm² |
Wire gauge (AWG) | max. 14 |
Cable outlet | 7,0 - 17,0 mm |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 100 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 16 A |
Rated voltage | 400 (600 V UL) V |
Rated impulse voltage | 6000 V |
Pollution degree | 3 |
Overvoltage category | III |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Ag (silver) |
Contact body material | PBT |
Customs tariff number | 85369010 |
Weight (g) | 48.395 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- The end user must take suitable safety measures to ensure that the connector cannot be disconnected accidentally.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
CAD files
99 4225 300 07
RD24 cable connector, Contacts: 6+PE, 7,0 - 17,0 mm, Shielding is not possible, solder, IP67, Vario
RD24, series 693, Power connectors
Order number |
99 4225 300 07
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | max. 0.75 mm² |
Wire gauge (AWG) | max. 20 |
Cable outlet | 7,0 - 17,0 mm |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 100 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 10 A |
Rated voltage | 250 V |
Rated impulse voltage | 4000 V |
Pollution degree | 3 |
Overvoltage category | III |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Ag (silver) |
Contact body material | PBT |
Customs tariff number | 85369010 |
Weight (g) | 42.15 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
CAD files
99 4201 300 07
RD24 cable connector, Contacts: 6+PE, 7,0 - 17,0 mm, Shielding is not possible, crimp (Crimp contacts must be ordered separately), IP67, Vario
RD24, series 693, Power connectors
Order number |
99 4201 300 07
|
Connector locking system | bolted |
Termination | crimp (Crimp contacts must be ordered separately) |
Wire gauge (mm) | see crimp contacts under accessories |
Cable outlet | 7,0 - 17,0 mm |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 100 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 10 A |
Rated voltage | 250 V |
Rated impulse voltage | 4000 V |
Pollution degree | 3 |
Overvoltage category | III |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | depending on crimp contact (accessory) |
Contact body material | PBT |
Customs tariff number | 85369010 |
Weight (g) | 41.786 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
CAD files
99 4217 300 07
RD24 cable connector, Contacts: 6+PE, 7,0 - 17,0 mm, Shielding is not possible, screw clamp, IP67, Vario
RD24, series 693, Power connectors
Order number |
99 4217 300 07
|
Connector locking system | bolted |
Termination | screw clamp |
Wire gauge (mm) | max. 1.50 mm² |
Wire gauge (AWG) | max. 16 |
Cable outlet | 7,0 - 17,0 mm |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 100 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 10 A |
Rated voltage | 250 V |
Rated impulse voltage | 4000 V |
Pollution degree | 3 |
Overvoltage category | III |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Ag (silver) |
Contact body material | PBT |
Customs tariff number | 85369010 |
Weight (g) | 51.386 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).