Ordering no:
Female angled connector overmoulded, shielded
Female angled connector overmoulded, shielded, Series 702
Available numbers of contacts
79 1402 72 02
M9 IP67 female angled connector, Contacts: 2, shielded, moulded on cable, IP67, Shielded cable, PUR black, 2 x 0,25 mm²
M9, series 702, Subminiature connectors
Order number |
79 1402 72 02
|
Connector locking system | bolted |
Termination | moulded on cable |
Wire gauge (mm) | 0.25 mm² |
Wire gauge (AWG) | 24 |
Cable length | 2 m |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 70 °C |
Lower limit temperature | -25 °C |
Rated current (40 °C) | 4 A |
Rated voltage | 125 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | II |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | PUR |
Cable data | |
Sheath material | PUR |
Single-lead insulation | PVC |
Single-lead structure | 14 x 0,15 mm |
Cable diameter | 5.3 |
Conductor resistance | 75Ω/Km |
Temperature range, moving cable, °C from | -5 |
Temperature range, moving cable, °C to | 70 |
Temperature range, fixed cable, °C from | -25 |
Temperature range, fixed cable, °C to | 70 |
Bending radius, fixed cable | Min. 53 mm |
Bending radius, moving cable | Min. 80 mm |
Customs tariff number | 85444290 |
Weight (g) | 96 |



Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
79 1402 75 02
M9 IP67 female angled connector, Contacts: 2, shielded, moulded on cable, IP67, Shielded cable, PUR black, 2 x 0,25 mm²
M9, series 702, Subminiature connectors
Order number |
79 1402 75 02
|
Connector locking system | bolted |
Termination | moulded on cable |
Wire gauge (mm) | 0.25 mm² |
Wire gauge (AWG) | 24 |
Cable length | 5 m |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 70 °C |
Lower limit temperature | -25 °C |
Rated current (40 °C) | 4 A |
Rated voltage | 125 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | II |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | PUR |
Cable data | |
Sheath material | PUR |
Single-lead insulation | PVC |
Single-lead structure | 14 x 0,15 mm |
Cable diameter | 5.3 |
Conductor resistance | 75Ω/Km |
Temperature range, moving cable, °C from | -5 |
Temperature range, moving cable, °C to | 70 |
Temperature range, fixed cable, °C from | -25 |
Temperature range, fixed cable, °C to | 70 |
Bending radius, fixed cable | Min. 53 mm |
Bending radius, moving cable | Min. 80 mm |
Customs tariff number | 85444290 |
Weight (g) | 224 |



Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
79 1406 72 03
M9 IP67 female angled connector, Contacts: 3, shielded, moulded on cable, IP67, Shielded cable, PUR black, 3 x 0,25 mm²
M9, series 702, Subminiature connectors
Order number |
79 1406 72 03
|
Connector locking system | bolted |
Termination | moulded on cable |
Wire gauge (mm) | 0.25 mm² |
Wire gauge (AWG) | 24 |
Cable length | 2 m |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 70 °C |
Lower limit temperature | -25 °C |
Rated current (40 °C) | 4 A |
Rated voltage | 125 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | II |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | PUR |
Cable data | |
Sheath material | PUR |
Single-lead insulation | PVC |
Single-lead structure | 14 x 0,15 mm |
Cable diameter | 5.3 |
Conductor resistance | 75Ω/Km |
Temperature range, moving cable, °C from | -5 |
Temperature range, moving cable, °C to | 70 |
Temperature range, fixed cable, °C from | -25 |
Temperature range, fixed cable, °C to | 70 |
Bending radius, fixed cable | Min. 53 mm |
Bending radius, moving cable | Min. 80 mm |
Customs tariff number | 85444290 |
Weight (g) | 96 |



Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
79 1406 75 03
M9 IP67 female angled connector, Contacts: 3, shielded, moulded on cable, IP67, Shielded cable, PUR black, 3 x 0,25 mm²
M9, series 702, Subminiature connectors
Order number |
79 1406 75 03
|
Connector locking system | bolted |
Termination | moulded on cable |
Wire gauge (mm) | 0.25 mm² |
Wire gauge (AWG) | 24 |
Cable length | 5 m |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 70 °C |
Lower limit temperature | -25 °C |
Rated current (40 °C) | 4 A |
Rated voltage | 125 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | II |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | PUR |
Cable data | |
Sheath material | PUR |
Single-lead insulation | PVC |
Single-lead structure | 14 x 0,15 mm |
Cable diameter | 5.3 |
Conductor resistance | 75Ω/Km |
Temperature range, moving cable, °C from | -5 |
Temperature range, moving cable, °C to | 70 |
Temperature range, fixed cable, °C from | -25 |
Temperature range, fixed cable, °C to | 70 |
Bending radius, fixed cable | Min. 53 mm |
Bending radius, moving cable | Min. 80 mm |
Customs tariff number | 85444290 |
Weight (g) | 220.5 |



Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
79 1410 72 04
M9 IP67 female angled connector, Contacts: 4, shielded, moulded on cable, IP67, Shielded cable, PUR black, 4 x 0,25 mm²
M9, series 702, Subminiature connectors
Order number |
79 1410 72 04
|
Connector locking system | bolted |
Termination | moulded on cable |
Wire gauge (mm) | 0.25 mm² |
Wire gauge (AWG) | 24 |
Cable length | 2 m |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 70 °C |
Lower limit temperature | -25 °C |
Rated current (40 °C) | 3 A |
Rated voltage | 125 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | II |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | PUR |
Cable data | |
Sheath material | PUR |
Single-lead insulation | PVC |
Single-lead structure | 14 x 0,15 mm |
Cable diameter | 5.3 |
Conductor resistance | 75Ω/Km |
Temperature range, moving cable, °C from | -5 |
Temperature range, moving cable, °C to | 70 |
Temperature range, fixed cable, °C from | -25 |
Temperature range, fixed cable, °C to | 70 |
Bending radius, fixed cable | Min. 53 mm |
Bending radius, moving cable | Min. 80 mm |
Customs tariff number | 85444290 |
Weight (g) | 96 |



Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
79 1410 75 04
M9 IP67 female angled connector, Contacts: 4, shielded, moulded on cable, IP67, Shielded cable, PUR black, 4 x 0,25 mm²
M9, series 702, Subminiature connectors
Order number |
79 1410 75 04
|
Connector locking system | bolted |
Termination | moulded on cable |
Wire gauge (mm) | 0.25 mm² |
Wire gauge (AWG) | 24 |
Cable length | 5 m |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 70 °C |
Lower limit temperature | -25 °C |
Rated current (40 °C) | 3 A |
Rated voltage | 125 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | II |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | PUR |
Cable data | |
Sheath material | PUR |
Single-lead insulation | PVC |
Single-lead structure | 14 x 0,15 mm |
Cable diameter | 5.3 |
Conductor resistance | 75Ω/Km |
Temperature range, moving cable, °C from | -5 |
Temperature range, moving cable, °C to | 70 |
Temperature range, fixed cable, °C from | -25 |
Temperature range, fixed cable, °C to | 70 |
Bending radius, fixed cable | Min. 53 mm |
Bending radius, moving cable | Min. 80 mm |
Customs tariff number | 85444290 |
Weight (g) | 223 |



Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
79 1414 72 05
M9 IP67 female angled connector, Contacts: 5, shielded, moulded on cable, IP67, Shielded cable, PUR black, 5 x 0,25 mm²
M9, series 702, Subminiature connectors
Order number |
79 1414 72 05
|
Connector locking system | bolted |
Termination | moulded on cable |
Wire gauge (mm) | 0.25 mm² |
Wire gauge (AWG) | 24 |
Cable length | 2 m |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 70 °C |
Lower limit temperature | -25 °C |
Rated current (40 °C) | 3 A |
Rated voltage | 125 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | II |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | PUR |
Cable data | |
Sheath material | PUR |
Single-lead insulation | PVC |
Single-lead structure | 14 x 0,15 mm |
Cable diameter | 5.3 |
Conductor resistance | 75Ω/Km |
Temperature range, moving cable, °C from | -5 |
Temperature range, moving cable, °C to | 70 |
Temperature range, fixed cable, °C from | -25 |
Temperature range, fixed cable, °C to | 70 |
Bending radius, fixed cable | Min. 53 mm |
Bending radius, moving cable | Min. 80 mm |
Customs tariff number | 85444290 |
Weight (g) | 96 |



Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
79 1414 75 05
M9 IP67 female angled connector, Contacts: 5, shielded, moulded on cable, IP67, Shielded cable, PUR black, 5 x 0,25 mm²
M9, series 702, Subminiature connectors
Order number |
79 1414 75 05
|
Connector locking system | bolted |
Termination | moulded on cable |
Wire gauge (mm) | 0.25 mm² |
Wire gauge (AWG) | 24 |
Cable length | 5 m |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 70 °C |
Lower limit temperature | -25 °C |
Rated current (40 °C) | 3 A |
Rated voltage | 125 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | II |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | PUR |
Cable data | |
Sheath material | PUR |
Single-lead insulation | PVC |
Single-lead structure | 14 x 0,15 mm |
Cable diameter | 5.3 |
Conductor resistance | 75Ω/Km |
Temperature range, moving cable, °C from | -5 |
Temperature range, moving cable, °C to | 70 |
Temperature range, fixed cable, °C from | -25 |
Temperature range, fixed cable, °C to | 70 |
Bending radius, fixed cable | Min. 53 mm |
Bending radius, moving cable | Min. 80 mm |
Customs tariff number | 85444290 |
Weight (g) | 220 |



Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
79 1422 72 07
M9 IP67 female angled connector, Contacts: 7, shielded, moulded on cable, IP67, Shielded cable, PUR black, 7 x 0,14 mm²
M9, series 702, Subminiature connectors
Order number |
79 1422 72 07
|
Connector locking system | bolted |
Termination | moulded on cable |
Wire gauge (mm) | 0.14 mm² |
Wire gauge (AWG) | 26 |
Cable length | 2 m |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 70 °C |
Lower limit temperature | -25 °C |
Rated current (40 °C) | 1 A |
Rated voltage | 125 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | II |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | PUR |
Cable data | |
Sheath material | PUR |
Single-lead insulation | PVC |
Single-lead structure | 18 x 0,10 mm |
Cable diameter | 5.3 |
Conductor resistance | 75Ω/Km |
Temperature range, moving cable, °C from | -5 |
Temperature range, moving cable, °C to | 70 |
Temperature range, fixed cable, °C from | -25 |
Temperature range, fixed cable, °C to | 70 |
Bending radius, fixed cable | Min. 53 mm |
Bending radius, moving cable | Min. 80 mm |
Customs tariff number | 85444290 |
Weight (g) | 95 |



Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
79 1422 75 07
M9 IP67 female angled connector, Contacts: 7, shielded, moulded on cable, IP67, Shielded cable, PUR black, 7 x 0,14 mm²
M9, series 702, Subminiature connectors
Order number |
79 1422 75 07
|
Connector locking system | bolted |
Termination | moulded on cable |
Wire gauge (mm) | 0.14 mm² |
Wire gauge (AWG) | 26 |
Cable length | 5 m |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 70 °C |
Lower limit temperature | -25 °C |
Rated current (40 °C) | 1 A |
Rated voltage | 125 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | II |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | PUR |
Cable data | |
Sheath material | PUR |
Single-lead insulation | PVC |
Single-lead structure | 18 x 0,10 mm |
Cable diameter | 5.3 |
Conductor resistance | 75Ω/Km |
Temperature range, moving cable, °C from | -5 |
Temperature range, moving cable, °C to | 70 |
Temperature range, fixed cable, °C from | -25 |
Temperature range, fixed cable, °C to | 70 |
Bending radius, fixed cable | Min. 53 mm |
Bending radius, moving cable | Min. 80 mm |
Customs tariff number | 85444290 |
Weight (g) | 221 |



Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
79 1426 72 08
M9 IP67 female angled connector, Contacts: 8, shielded, moulded on cable, IP67, Shielded cable, PUR black, 8 x 0,14 mm²
M9, series 702, Subminiature connectors
Order number |
79 1426 72 08
|
Connector locking system | bolted |
Termination | moulded on cable |
Wire gauge (mm) | 0.14 mm² |
Wire gauge (AWG) | 26 |
Cable length | 2 m |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 70 °C |
Lower limit temperature | -25 °C |
Rated current (40 °C) | 1 A |
Rated voltage | 125 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | II |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | PUR |
Cable data | |
Sheath material | PUR |
Single-lead insulation | PVC |
Single-lead structure | 18 x 0,10 mm |
Cable diameter | 5.3 |
Conductor resistance | 75Ω/Km |
Temperature range, moving cable, °C from | -5 |
Temperature range, moving cable, °C to | 70 |
Temperature range, fixed cable, °C from | -25 |
Temperature range, fixed cable, °C to | 70 |
Bending radius, fixed cable | Min. 53 mm |
Bending radius, moving cable | Min. 80 mm |
Customs tariff number | 85444290 |
Weight (g) | 96 |



Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
79 1426 75 08
M9 IP67 female angled connector, Contacts: 8, shielded, moulded on cable, IP67, Shielded cable, PUR black, 8 x 0,14 mm²
M9, series 702, Subminiature connectors
Order number |
79 1426 75 08
|
Connector locking system | bolted |
Termination | moulded on cable |
Wire gauge (mm) | 0.14 mm² |
Wire gauge (AWG) | 26 |
Cable length | 5 m |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 70 °C |
Lower limit temperature | -25 °C |
Rated current (40 °C) | 1 A |
Rated voltage | 125 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | II |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | PUR |
Cable data | |
Sheath material | PUR |
Single-lead insulation | PVC |
Single-lead structure | 18 x 0,10 mm |
Cable diameter | 5.3 |
Conductor resistance | 75Ω/Km |
Temperature range, moving cable, °C from | -5 |
Temperature range, moving cable, °C to | 70 |
Temperature range, fixed cable, °C from | -25 |
Temperature range, fixed cable, °C to | 70 |
Bending radius, fixed cable | Min. 53 mm |
Bending radius, moving cable | Min. 80 mm |
Customs tariff number | 85444290 |
Weight (g) | 223 |



Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Contact to customer service
Do you have any questions regarding our products or do you wish an individual offer?