Ordering no:
Cable plug connector with cable clamp, CRIMP connection, shieldable, cable outlet 4 - 6 mm
Cable plug connector with cable clamp, CRIMP connection, shieldable, cable outlet 4 - 6 mm, Serier 581
Available numbers of contacts
99 2009 700 04
M16 IP40 cable connector, Contacts: 4, 4,0 - 6,0 mm, shieldable, crimp (Crimp contacts must be ordered separately), IP40
M16, series 581, Miniature connectors
Beställningsnummer |
99 2009 700 04
|
Kontaktdonslåsning | bolted |
Anslutning | crimp (Crimp contacts must be ordered separately) |
Tvärsnitt (mm) | see crimp contacts under accessories |
Kabeluttag | 4,0 - 6,0 mm |
Kapslingsklass | IP40 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 100 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 5 A |
Märkspänning | 250 V |
Märksstötsspänning | 1500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | depending on crimp contact (accessory) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 26.5 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Nedladdningar
Produktblad
CAD-filer
99 2013 700 05
M16 IP40 cable connector, Contacts: 5, 4,0 - 6,0 mm, shieldable, crimp (Crimp contacts must be ordered separately), IP40
M16, series 581, Miniature connectors
Beställningsnummer |
99 2013 700 05
|
Kontaktdonslåsning | bolted |
Anslutning | crimp (Crimp contacts must be ordered separately) |
Tvärsnitt (mm) | see crimp contacts under accessories |
Kabeluttag | 4,0 - 6,0 mm |
Kapslingsklass | IP40 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 100 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 5 A |
Märkspänning | 250 V |
Märksstötsspänning | 1500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | depending on crimp contact (accessory) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 26.8 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Nedladdningar
Produktblad
CAD-filer
99 2021 700 06
M16 IP40 cable connector, Contacts: 6 DIN, 4,0 - 6,0 mm, shieldable, crimp (Crimp contacts must be ordered separately), IP40
M16, series 581, Miniature connectors
Beställningsnummer |
99 2021 700 06
|
Kontaktdonslåsning | bolted |
Anslutning | crimp (Crimp contacts must be ordered separately) |
Tvärsnitt (mm) | see crimp contacts under accessories |
Kabeluttag | 4,0 - 6,0 mm |
Kapslingsklass | IP40 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 100 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 5 A |
Märkspänning | 250 V |
Märksstötsspänning | 1500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | depending on crimp contact (accessory) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 26.833 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Nedladdningar
Produktblad
99 2025 700 07
M16 IP40 cable connector, Contacts: 7, 4,0 - 6,0 mm, shieldable, crimp (Crimp contacts must be ordered separately), IP40
M16, series 581, Miniature connectors
Beställningsnummer |
99 2025 700 07
|
Kontaktdonslåsning | bolted |
Anslutning | crimp (Crimp contacts must be ordered separately) |
Tvärsnitt (mm) | see crimp contacts under accessories |
Kabeluttag | 4,0 - 6,0 mm |
Kapslingsklass | IP40 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 100 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 5 A |
Märkspänning | 125 V |
Märksstötsspänning | 800 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | depending on crimp contact (accessory) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 26.763 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Nedladdningar
Produktblad
CAD-filer
99 2061 700 08
M16 IP40 cable connector, Contacts: 8 DIN, 4,0 - 6,0 mm, shieldable, crimp (Crimp contacts must be ordered separately), IP40
M16, series 581, Miniature connectors
Beställningsnummer |
99 2061 700 08
|
Kontaktdonslåsning | bolted |
Anslutning | crimp (Crimp contacts must be ordered separately) |
Tvärsnitt (mm) | see crimp contacts under accessories |
Kabeluttag | 4,0 - 6,0 mm |
Kapslingsklass | IP40 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 100 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 5 A |
Märkspänning | 60 V |
Märksstötsspänning | 500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | depending on crimp contact (accessory) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 26.673 |





Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Nedladdningar
Produktblad
Contact to customer service
Do you have any questions regarding our products or do you wish an individual offer?