Ordering no:
Female panel mount connector, solder, screwed from front, 2 - 8 contacts
Female panel mount connector, solder, screwed from front, 2 - 8 contacts, Serier 581/ 680/ 682
Available numbers of contacts
09 0304 80 02
M16 IP40 female panel mount connector, Contacts: 2, Shielding is not possible, solder, IP40
M16, series 682, Miniature connectors
Beställningsnummer |
09 0304 80 02
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0,75 mm² |
Tvärsnitt (AWG) | 20 |
Kapslingsklass | IP40 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 85 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 7 A |
Märkspänning | 250 V |
Märksstötsspänning | 1500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 5 mΩ |
Insulation resistance | ≥ 1010Ω |
Kontaktmaterial | CuSn (bronze) |
Kontaktplätering | Ag (silver) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 8.697 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
Nedladdningar
Produktblad
CAD-filer
09 0304 89 02
M16 IP40 female panel mount connector, Contacts: 2, Shielding is not possible, solder, IP40
M16, series 682, Miniature connectors
Beställningsnummer |
09 0304 89 02
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0,75 mm² |
Tvärsnitt (AWG) | 20 |
Kapslingsklass | IP40 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 85 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 7 A |
Märkspänning | 250 V |
Märksstötsspänning | 1500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 3 mΩ |
Insulation resistance | ≥ 1010Ω |
Kontaktmaterial | CuSn (bronze) |
Kontaktplätering | Au (gold) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 8.697 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
Nedladdningar
Produktblad
CAD-filer
09 0308 80 03
M16 IP40 female panel mount connector, Contacts: 3, Shielding is not possible, solder, IP40
M16, series 682, Miniature connectors
Beställningsnummer |
09 0308 80 03
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0,75 mm² |
Tvärsnitt (AWG) | 20 |
Kapslingsklass | IP40 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 85 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 7 A |
Märkspänning | 250 V |
Märksstötsspänning | 1500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 5 mΩ |
Insulation resistance | ≥ 1010Ω |
Kontaktmaterial | CuSn (bronze) |
Kontaktplätering | Ag (silver) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 8.804 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
Nedladdningar
Produktblad
CAD-filer
09 0308 89 03
M16 IP40 female panel mount connector, Contacts: 3, Shielding is not possible, solder, IP40
M16, series 682, Miniature connectors
Beställningsnummer |
09 0308 89 03
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0,75 mm² |
Tvärsnitt (AWG) | 20 |
Kapslingsklass | IP40 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 85 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 7 A |
Märkspänning | 250 V |
Märksstötsspänning | 1500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 3 mΩ |
Insulation resistance | ≥ 1010Ω |
Kontaktmaterial | CuSn (bronze) |
Kontaktplätering | Au (gold) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 8.804 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
Nedladdningar
Produktblad
CAD-filer
09 0312 80 04
M16 IP40 female panel mount connector, Contacts: 4, Shielding is not possible, solder, IP40
M16, series 682, Miniature connectors
Beställningsnummer |
09 0312 80 04
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0,75 mm² |
Tvärsnitt (AWG) | 20 |
Kapslingsklass | IP40 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 85 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 6 A |
Märkspänning | 250 V |
Märksstötsspänning | 1500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 5 mΩ |
Insulation resistance | ≥ 1010Ω |
Kontaktmaterial | CuSn (bronze) |
Kontaktplätering | Ag (silver) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 9.017 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
Nedladdningar
Produktblad
CAD-filer
09 0312 89 04
M16 IP40 female panel mount connector, Contacts: 4, Shielding is not possible, solder, IP40
M16, series 682, Miniature connectors
Beställningsnummer |
09 0312 89 04
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0,75 mm² |
Tvärsnitt (AWG) | 20 |
Kapslingsklass | IP40 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 85 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 6 A |
Märkspänning | 250 V |
Märksstötsspänning | 1500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 3 mΩ |
Insulation resistance | ≥ 1010Ω |
Kontaktmaterial | CuSn (bronze) |
Kontaktplätering | Au (gold) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 9.017 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
Nedladdningar
Produktblad
CAD-filer
09 0320 80 05
M16 IP40 female panel mount connector, Contacts: 5, Shielding is not possible, solder, IP40
M16, series 682, Miniature connectors
Beställningsnummer |
09 0320 80 05
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0,75 mm² |
Tvärsnitt (AWG) | 20 |
Kapslingsklass | IP40 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 85 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 6 A |
Märkspänning | 60 V |
Märksstötsspänning | 500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 5 mΩ |
Insulation resistance | ≥ 1010Ω |
Kontaktmaterial | CuSn (bronze) |
Kontaktplätering | Ag (silver) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 8.69 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
Nedladdningar
Produktblad
CAD-filer
09 0320 89 05
M16 IP40 female panel mount connector, Contacts: 5, Shielding is not possible, solder, IP40
M16, series 682, Miniature connectors
Beställningsnummer |
09 0320 89 05
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0,75 mm² |
Tvärsnitt (AWG) | 20 |
Kapslingsklass | IP40 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 85 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 6 A |
Märkspänning | 60 V |
Märksstötsspänning | 500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 3 mΩ |
Insulation resistance | ≥ 1010Ω |
Kontaktmaterial | CuSn (bronze) |
Kontaktplätering | Au (gold) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 8.695 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
Nedladdningar
Produktblad
CAD-filer
09 0324 80 06
M16 IP40 female panel mount connector, Contacts: 6, Shielding is not possible, solder, IP40
M16, series 682, Miniature connectors
Beställningsnummer |
09 0324 80 06
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0,75 mm² |
Tvärsnitt (AWG) | 20 |
Kapslingsklass | IP40 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 85 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 5 A |
Märkspänning | 250 V |
Märksstötsspänning | 1500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 5 mΩ |
Insulation resistance | ≥ 1010Ω |
Kontaktmaterial | CuSn (bronze) |
Kontaktplätering | Ag (silver) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 9.266 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
Nedladdningar
Produktblad
CAD-filer
09 0324 89 06
M16 IP40 female panel mount connector, Contacts: 6, Shielding is not possible, solder, IP40
M16, series 682, Miniature connectors
Beställningsnummer |
09 0324 89 06
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0,75 mm² |
Tvärsnitt (AWG) | 20 |
Kapslingsklass | IP40 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 85 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 5 A |
Märkspänning | 250 V |
Märksstötsspänning | 1500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 3 mΩ |
Insulation resistance | ≥ 1010Ω |
Kontaktmaterial | CuSn (bronze) |
Kontaktplätering | Au (gold) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 9.266 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
Nedladdningar
Produktblad
CAD-filer
09 0328 80 07
M16 IP40 female panel mount connector, Contacts: 7, Shielding is not possible, solder, IP40
M16, series 682, Miniature connectors
Beställningsnummer |
09 0328 80 07
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0,75 mm² |
Tvärsnitt (AWG) | 20 |
Kapslingsklass | IP40 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 85 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 5 A |
Märkspänning | 125 V |
Märksstötsspänning | 800 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 5 mΩ |
Insulation resistance | ≥ 1010Ω |
Kontaktmaterial | CuSn (bronze) |
Kontaktplätering | Ag (silver) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 9.41 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
Nedladdningar
Produktblad
CAD-filer
09 0328 89 07
M16 IP40 female panel mount connector, Contacts: 7, Shielding is not possible, solder, IP40
M16, series 682, Miniature connectors
Beställningsnummer |
09 0328 89 07
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0,75 mm² |
Tvärsnitt (AWG) | 20 |
Kapslingsklass | IP40 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 85 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 5 A |
Märkspänning | 125 V |
Märksstötsspänning | 800 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 3 mΩ |
Insulation resistance | ≥ 1010Ω |
Kontaktmaterial | CuSn (bronze) |
Kontaktplätering | Au (gold) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 9.41 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
Nedladdningar
Produktblad
CAD-filer
09 0474 80 08
M16 IP40 female panel mount connector, Contacts: 8, Shielding is not possible, solder, IP40
M16, series 682, Miniature connectors
Beställningsnummer |
09 0474 80 08
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0,75 mm² |
Tvärsnitt (AWG) | 20 |
Kapslingsklass | IP40 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 85 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 5 A |
Märkspänning | 60 V |
Märksstötsspänning | 500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 5 mΩ |
Insulation resistance | ≥ 1010Ω |
Kontaktmaterial | CuSn (bronze) |
Kontaktplätering | Ag (silver) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 8.899 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
Nedladdningar
Produktblad
CAD-filer
09 0474 89 08
M16 IP40 female panel mount connector, Contacts: 8, Shielding is not possible, solder, IP40
M16, series 682, Miniature connectors
Beställningsnummer |
09 0474 89 08
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0,75 mm² |
Tvärsnitt (AWG) | 20 |
Kapslingsklass | IP40 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 85 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 5 A |
Märkspänning | 60 V |
Märksstötsspänning | 500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 3 mΩ |
Insulation resistance | ≥ 1010Ω |
Kontaktmaterial | CuSn (bronze) |
Kontaktplätering | Au (gold) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 8.907 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
Nedladdningar
Produktblad
CAD-filer
Contact to customer service