Ordering no:
Male panel mount connector, solder
Male panel mount connector, solder, Serier 581/ 680/ 682
Available numbers of contacts
09 0303 00 02
M16 IP40 male panel mount connector, Contacts: 2, Shielding is not possible, solder, IP40
M16, series 680, Miniature connectors
Beställningsnummer |
09 0303 00 02
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0.75 mm² |
Tvärsnitt (AWG) | 20 |
Kapslingsklass | IP40 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 85 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 7 A |
Märkspänning | 250 V |
Märksstötsspänning | 1500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | CuZn (brass) |
Kontaktplätering | Ag (silver) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Kontakthusmaterial | Zinc die-cast nickel-plated |
Customs tariff number | 85369010 |
Weight (g) | 10.286 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
Nedladdningar
Produktblad
CAD-filer
09 0303 09 02
M16 IP40 male panel mount connector, Contacts: 2, Shielding is not possible, solder, IP40
M16, series 680, Miniature connectors
Beställningsnummer |
09 0303 09 02
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0.75 mm² |
Tvärsnitt (AWG) | 20 |
Kapslingsklass | IP40 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 85 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 7 A |
Märkspänning | 250 V |
Märksstötsspänning | 1500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | CuZn (brass) |
Kontaktplätering | Au (gold) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Kontakthusmaterial | Zinc die-cast nickel-plated |
Customs tariff number | 85369010 |
Weight (g) | 10.295 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
Nedladdningar
Produktblad
CAD-filer
09 0307 00 03
M16 IP40 male panel mount connector, Contacts: 3 DIN, Shielding is not possible, solder, IP40
M16, series 680, Miniature connectors
Beställningsnummer |
09 0307 00 03
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0.75 mm² |
Tvärsnitt (AWG) | 20 |
Kapslingsklass | IP40 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 85 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 7 A |
Märkspänning | 250 V |
Märksstötsspänning | 1500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | CuZn (brass) |
Kontaktplätering | Ag (silver) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Kontakthusmaterial | Zinc die-cast nickel-plated |
Customs tariff number | 85369010 |
Weight (g) | 10.527 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
Nedladdningar
Produktblad
CAD-filer
09 0307 09 03
M16 IP40 male panel mount connector, Contacts: 3 DIN, Shielding is not possible, solder, IP40
M16, series 680, Miniature connectors
Beställningsnummer |
09 0307 09 03
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0.75 mm² |
Tvärsnitt (AWG) | 20 |
Kapslingsklass | IP40 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 85 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 7 A |
Märkspänning | 250 V |
Märksstötsspänning | 1500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | CuZn (brass) |
Kontaktplätering | Au (gold) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Kontakthusmaterial | Zinc die-cast nickel-plated |
Customs tariff number | 85369010 |
Weight (g) | 10.533 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
Nedladdningar
Produktblad
CAD-filer
09 0311 00 04
M16 IP40 male panel mount connector, Contacts: 4, Shielding is not possible, solder, IP40
M16, series 680, Miniature connectors
Beställningsnummer |
09 0311 00 04
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0.75 mm² |
Tvärsnitt (AWG) | 20 |
Kapslingsklass | IP40 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 85 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 6 A |
Märkspänning | 250 V |
Märksstötsspänning | 1500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | CuZn (brass) |
Kontaktplätering | Ag (silver) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Kontakthusmaterial | Zinc die-cast nickel-plated |
Customs tariff number | 85369010 |
Weight (g) | 10.765 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
Nedladdningar
Produktblad
CAD-filer
09 0311 09 04
M16 IP40 male panel mount connector, Contacts: 4, Shielding is not possible, solder, IP40
M16, series 680, Miniature connectors
Beställningsnummer |
09 0311 09 04
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0.75 mm² |
Tvärsnitt (AWG) | 20 |
Kapslingsklass | IP40 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 85 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 6 A |
Märkspänning | 250 V |
Märksstötsspänning | 1500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | CuZn (brass) |
Kontaktplätering | Au (gold) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Kontakthusmaterial | Zinc die-cast nickel-plated |
Customs tariff number | 85369010 |
Weight (g) | 10.745 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
Nedladdningar
Produktblad
CAD-filer
09 0315 00 05
M16 IP40 male panel mount connector, Contacts: 5, Shielding is not possible, solder, IP40
M16, series 680, Miniature connectors
Beställningsnummer |
09 0315 00 05
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0.75 mm² |
Tvärsnitt (AWG) | 20 |
Kapslingsklass | IP40 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 85 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 6 A |
Märkspänning | 250 V |
Märksstötsspänning | 1500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | CuZn (brass) |
Kontaktplätering | Ag (silver) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Kontakthusmaterial | Zinc die-cast nickel-plated |
Customs tariff number | 85369010 |
Weight (g) | 10.776 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
Nedladdningar
Produktblad
CAD-filer
09 0315 09 05
M16 IP40 male panel mount connector, Contacts: 5, Shielding is not possible, solder, IP40
M16, series 680, Miniature connectors
Beställningsnummer |
09 0315 09 05
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0.75 mm² |
Tvärsnitt (AWG) | 20 |
Kapslingsklass | IP40 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 85 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 6 A |
Märkspänning | 250 V |
Märksstötsspänning | 1500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | CuZn (brass) |
Kontaktplätering | Au (gold) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Kontakthusmaterial | Zinc die-cast nickel-plated |
Customs tariff number | 85369010 |
Weight (g) | 10.776 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
Nedladdningar
Produktblad
CAD-filer
09 0319 00 05
M16 IP40 male panel mount connector, Contacts: 5 (stereo), Shielding is not possible, solder, IP40
M16, series 680, Miniature connectors
Beställningsnummer |
09 0319 00 05
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0.75 mm² |
Tvärsnitt (AWG) | 20 |
Kapslingsklass | IP40 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 85 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 6 A |
Märkspänning | 60 V |
Märksstötsspänning | 500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | CuZn (brass) |
Kontaktplätering | Ag (silver) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Kontakthusmaterial | Zinc die-cast nickel-plated |
Customs tariff number | 85369010 |
Weight (g) | 10.979 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
Nedladdningar
Produktblad
CAD-filer
09 0319 09 05
M16 IP40 male panel mount connector, Contacts: 5 (stereo), Shielding is not possible, solder, IP40
M16, series 680, Miniature connectors
Beställningsnummer |
09 0319 09 05
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0.75 mm² |
Tvärsnitt (AWG) | 20 |
Kapslingsklass | IP40 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 85 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 6 A |
Märkspänning | 60 V |
Märksstötsspänning | 500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | CuZn (brass) |
Kontaktplätering | Au (gold) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Kontakthusmaterial | Zinc die-cast nickel-plated |
Customs tariff number | 85369010 |
Weight (g) | 10.993 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
Nedladdningar
Produktblad
CAD-filer
09 0323 00 06
M16 IP40 male panel mount connector, Contacts: 6 DIN, Shielding is not possible, solder, IP40
M16, series 680, Miniature connectors
Beställningsnummer |
09 0323 00 06
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0.75 mm² |
Tvärsnitt (AWG) | 20 |
Kapslingsklass | IP40 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 85 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 5 A |
Märkspänning | 250 V |
Märksstötsspänning | 1500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | CuZn (brass) |
Kontaktplätering | Ag (silver) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Kontakthusmaterial | Zinc die-cast nickel-plated |
Customs tariff number | 85369010 |
Weight (g) | 11.226 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
Nedladdningar
Produktblad
CAD-filer
09 0323 09 06
M16 IP40 male panel mount connector, Contacts: 6 DIN, Shielding is not possible, solder, IP40
M16, series 680, Miniature connectors
Beställningsnummer |
09 0323 09 06
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0.75 mm² |
Tvärsnitt (AWG) | 20 |
Kapslingsklass | IP40 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 85 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 5 A |
Märkspänning | 250 V |
Märksstötsspänning | 1500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | CuZn (brass) |
Kontaktplätering | Au (gold) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Kontakthusmaterial | Zinc die-cast nickel-plated |
Customs tariff number | 85369010 |
Weight (g) | 11.234 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
Nedladdningar
Produktblad
CAD-filer
09 0327 00 07
M16 IP40 male panel mount connector, Contacts: 7, Shielding is not possible, solder, IP40
M16, series 680, Miniature connectors
Beställningsnummer |
09 0327 00 07
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0.75 mm² |
Tvärsnitt (AWG) | 20 |
Kapslingsklass | IP40 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 85 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 5 A |
Märkspänning | 125 V |
Märksstötsspänning | 800 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | CuZn (brass) |
Kontaktplätering | Ag (silver) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Kontakthusmaterial | Zinc die-cast nickel-plated |
Customs tariff number | 85369010 |
Weight (g) | 11.457 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
Nedladdningar
Produktblad
CAD-filer
09 0327 09 07
M16 IP40 male panel mount connector, Contacts: 7, Shielding is not possible, solder, IP40
M16, series 680, Miniature connectors
Beställningsnummer |
09 0327 09 07
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0.75 mm² |
Tvärsnitt (AWG) | 20 |
Kapslingsklass | IP40 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 85 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 5 A |
Märkspänning | 125 V |
Märksstötsspänning | 800 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | CuZn (brass) |
Kontaktplätering | Au (gold) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Kontakthusmaterial | Zinc die-cast nickel-plated |
Customs tariff number | 85369010 |
Weight (g) | 11.449 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
Nedladdningar
Produktblad
CAD-filer
09 1583 00 07
M16 IP40 male panel mount connector, Contacts: 7 DIN, Shielding is not possible, solder, IP40
M16, series 680, Miniature connectors
Beställningsnummer |
09 1583 00 07
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0.75 mm² |
Tvärsnitt (AWG) | 20 |
Kapslingsklass | IP40 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 85 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 5 A |
Märkspänning | 60 V |
Märksstötsspänning | 500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | CuZn (brass) |
Kontaktplätering | Ag (silver) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Kontakthusmaterial | Zinc die-cast nickel-plated |
Customs tariff number | 85369010 |
Weight (g) | 11.45 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
Nedladdningar
Produktblad
CAD-filer
09 0473 00 08
M16 IP40 male panel mount connector, Contacts: 8 DIN, Shielding is not possible, solder, IP40
M16, series 680, Miniature connectors
Beställningsnummer |
09 0473 00 08
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0.75 mm² |
Tvärsnitt (AWG) | 20 |
Kapslingsklass | IP40 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 85 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 5 A |
Märkspänning | 60 V |
Märksstötsspänning | 500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | CuZn (brass) |
Kontaktplätering | Ag (silver) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Kontakthusmaterial | Zinc die-cast nickel-plated |
Customs tariff number | 85369010 |
Weight (g) | 11.683 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
Nedladdningar
Produktblad
CAD-filer
09 0473 09 08
M16 IP40 male panel mount connector, Contacts: 8 DIN, Shielding is not possible, solder, IP40
M16, series 680, Miniature connectors
Beställningsnummer |
09 0473 09 08
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0.75 mm² |
Tvärsnitt (AWG) | 20 |
Kapslingsklass | IP40 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 85 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 5 A |
Märkspänning | 60 V |
Märksstötsspänning | 500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | CuZn (brass) |
Kontaktplätering | Au (gold) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Kontakthusmaterial | Zinc die-cast nickel-plated |
Customs tariff number | 85369010 |
Weight (g) | 11.679 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
Nedladdningar
Produktblad
CAD-filer
09 0331 00 12
M16 IP40 male panel mount connector, Contacts: 12, Shielding is not possible, solder, IP40
M16, series 680, Miniature connectors
Beställningsnummer |
09 0331 00 12
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0.25 mm² |
Tvärsnitt (AWG) | 24 |
Kapslingsklass | IP40 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 85 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 3 A |
Märkspänning | 60 V |
Märksstötsspänning | 500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | CuZn (brass) |
Kontaktplätering | Au (gold) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Kontakthusmaterial | Zinc die-cast nickel-plated |
Customs tariff number | 85369010 |
Weight (g) | 11.144 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
Nedladdningar
Produktblad
CAD-filer
09 0053 00 14
M16 IP40 male panel mount connector, Contacts: 14, Shielding is not possible, solder, IP40
M16, series 680, Miniature connectors
Beställningsnummer |
09 0053 00 14
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0.25 mm² |
Tvärsnitt (AWG) | 24 |
Kapslingsklass | IP40 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 85 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 3 A |
Märkspänning | 60 V |
Märksstötsspänning | 500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | CuZn (brass) |
Kontaktplätering | Au (gold) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Kontakthusmaterial | Zinc die-cast nickel-plated |
Customs tariff number | 85369010 |
Weight (g) | 11.362 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
Nedladdningar
Produktblad
CAD-filer
09 0339 00 16
M16 IP40 male panel mount connector, Contacts: 16, Shielding is not possible, solder, IP40
M16, series 680, Miniature connectors
Beställningsnummer |
09 0339 00 16
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0.25 mm² |
Tvärsnitt (AWG) | 24 |
Kapslingsklass | IP40 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 85 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 3 A |
Märkspänning | 60 V |
Märksstötsspänning | 500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | CuZn (brass) |
Kontaktplätering | Au (gold) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Kontakthusmaterial | Zinc die-cast nickel-plated |
Customs tariff number | 85369010 |
Weight (g) | 11.581 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
Nedladdningar
Produktblad
CAD-filer
09 0335 00 19
M16 IP40 male panel mount connector, Contacts: 19, Shielding is not possible, solder, IP40
M16, series 680, Miniature connectors
Beställningsnummer |
09 0335 00 19
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0.25 mm² |
Tvärsnitt (AWG) | 24 |
Kapslingsklass | IP40 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 85 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 3 A |
Märkspänning | 60 V |
Märksstötsspänning | 500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | CuZn (brass) |
Kontaktplätering | Au (gold) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Kontakthusmaterial | Zinc die-cast nickel-plated |
Customs tariff number | 85369010 |
Weight (g) | 11.91 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
Nedladdningar
Produktblad
CAD-filer
09 0197 00 24
M16 IP40 male panel mount connector, Contacts: 24, Shielding is not possible, solder, IP40
M16, series 680, Miniature connectors
Beställningsnummer |
09 0197 00 24
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0.14 mm² |
Tvärsnitt (AWG) | 26 |
Kapslingsklass | IP40 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 85 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 1 A |
Märkspänning | 60 V |
Märksstötsspänning | 500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | CuZn (brass) |
Kontaktplätering | Au (gold) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Kontakthusmaterial | Zinc die-cast nickel-plated |
Customs tariff number | 85369010 |
Weight (g) | 11.224 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
Nedladdningar
Produktblad
CAD-filer
Contact to customer service