Ordering no:
Male angled connector, cable outlet 4-6 mm
Male angled connector, cable outlet 4-6 mm, Serier 723
Available numbers of contacts
99 0101 106 02
M16 IP67 male angled connector, Contacts: 2, 4,0 - 6,0 mm, Shielding is not possible, solder, IP67
M16, series 723, Miniature connectors
Beställningsnummer |
99 0101 106 02
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0.75 mm² |
Tvärsnitt (AWG) | 20 |
Kabeluttag | 4,0 - 6,0 mm |
Kapslingsklass | IP67 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 95 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 7 A |
Märkspänning | 250 V |
Märksstötsspänning | 1500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | CuZn (brass) |
Kontaktplätering | Ag (silver) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Kontakthusmaterial | PA |
Customs tariff number | 85369010 |
Weight (g) | 36.971 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Nedladdningar
Produktblad
CAD-filer
99 0101 118 02
M16 IP67 male angled connector, Contacts: 2, 4,0 - 6,0 mm, Shielding is not possible, solder, IP67
M16, series 723, Miniature connectors
Beställningsnummer |
99 0101 118 02
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0.75 mm² |
Tvärsnitt (AWG) | 20 |
Kabeluttag | 4,0 - 6,0 mm |
Kapslingsklass | IP67 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 95 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 7 A |
Märkspänning | 250 V |
Märksstötsspänning | 1500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | CuZn (brass) |
Kontaktplätering | Au (gold) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Kontakthusmaterial | PA |
Customs tariff number | 85369010 |
Weight (g) | 36.971 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Nedladdningar
Produktblad
CAD-filer
99 0105 106 03
M16 IP67 male angled connector, Contacts: 3 DIN, 4,0 - 6,0 mm, Shielding is not possible, solder, IP67
M16, series 723, Miniature connectors
Beställningsnummer |
99 0105 106 03
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0.75 mm² |
Tvärsnitt (AWG) | 20 |
Kabeluttag | 4,0 - 6,0 mm |
Kapslingsklass | IP67 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 95 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 7 A |
Märkspänning | 250 V |
Märksstötsspänning | 1500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | CuZn (brass) |
Kontaktplätering | Ag (silver) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Kontakthusmaterial | PA |
Customs tariff number | 85369010 |
Weight (g) | 37.2 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Nedladdningar
Produktblad
CAD-filer
99 0105 118 03
M16 IP67 male angled connector, Contacts: 3 DIN, 4,0 - 6,0 mm, Shielding is not possible, solder, IP67
M16, series 723, Miniature connectors
Beställningsnummer |
99 0105 118 03
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0.75 mm² |
Tvärsnitt (AWG) | 20 |
Kabeluttag | 4,0 - 6,0 mm |
Kapslingsklass | IP67 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 95 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 7 A |
Märkspänning | 250 V |
Märksstötsspänning | 1500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | CuZn (brass) |
Kontaktplätering | Au (gold) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Kontakthusmaterial | PA |
Customs tariff number | 85369010 |
Weight (g) | 37.2 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Nedladdningar
Produktblad
CAD-filer
99 0109 106 04
M16 IP67 male angled connector, Contacts: 4, 4,0 - 6,0 mm, Shielding is not possible, solder, IP67
M16, series 723, Miniature connectors
Beställningsnummer |
99 0109 106 04
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0.75 mm² |
Tvärsnitt (AWG) | 20 |
Kabeluttag | 4,0 - 6,0 mm |
Kapslingsklass | IP67 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 95 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 6 A |
Märkspänning | 250 V |
Märksstötsspänning | 1500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | CuZn (brass) |
Kontaktplätering | Ag (silver) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Kontakthusmaterial | PA |
Customs tariff number | 85369010 |
Weight (g) | 37.411 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Nedladdningar
Produktblad
CAD-filer
99 0109 118 04
M16 IP67 male angled connector, Contacts: 4, 4,0 - 6,0 mm, Shielding is not possible, solder, IP67
M16, series 723, Miniature connectors
Beställningsnummer |
99 0109 118 04
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0.75 mm² |
Tvärsnitt (AWG) | 20 |
Kabeluttag | 4,0 - 6,0 mm |
Kapslingsklass | IP67 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 95 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 6 A |
Märkspänning | 250 V |
Märksstötsspänning | 1500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | CuZn (brass) |
Kontaktplätering | Au (gold) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Kontakthusmaterial | PA |
Customs tariff number | 85369010 |
Weight (g) | 37.42 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Nedladdningar
Produktblad
CAD-filer
99 0113 106 05
M16 IP67 male angled connector, Contacts: 5, 4,0 - 6,0 mm, Shielding is not possible, solder, IP67
M16, series 723, Miniature connectors
Beställningsnummer |
99 0113 106 05
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0.75 mm² |
Tvärsnitt (AWG) | 20 |
Kabeluttag | 4,0 - 6,0 mm |
Kapslingsklass | IP67 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 95 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 6 A |
Märkspänning | 250 V |
Märksstötsspänning | 1500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | CuZn (brass) |
Kontaktplätering | Ag (silver) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Kontakthusmaterial | PA |
Customs tariff number | 85369010 |
Weight (g) | 37.659 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Nedladdningar
Produktblad
CAD-filer
99 0113 118 05
M16 IP67 male angled connector, Contacts: 5, 4,0 - 6,0 mm, Shielding is not possible, solder, IP67
M16, series 723, Miniature connectors
Beställningsnummer |
99 0113 118 05
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0.75 mm² |
Tvärsnitt (AWG) | 20 |
Kabeluttag | 4,0 - 6,0 mm |
Kapslingsklass | IP67 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 95 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 6 A |
Märkspänning | 250 V |
Märksstötsspänning | 1500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | CuZn (brass) |
Kontaktplätering | Au (gold) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Kontakthusmaterial | PA |
Customs tariff number | 85369010 |
Weight (g) | 37.659 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Nedladdningar
Produktblad
CAD-filer
99 0117 118 05
M16 IP67 male angled connector, Contacts: 5 (stereo), 4,0 - 6,0 mm, Shielding is not possible, solder, IP67
M16, series 723, Miniature connectors
Beställningsnummer |
99 0117 118 05
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0.75 mm² |
Tvärsnitt (AWG) | 20 |
Kabeluttag | 4,0 - 6,0 mm |
Kapslingsklass | IP67 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 95 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 6 A |
Märkspänning | 60 V |
Märksstötsspänning | 500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | CuZn (brass) |
Kontaktplätering | Au (gold) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Kontakthusmaterial | PA |
Customs tariff number | 85369010 |
Weight (g) | 37.653 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Nedladdningar
Produktblad
CAD-filer
99 0121 106 06
M16 IP67 male angled connector, Contacts: 6 DIN, 4,0 - 6,0 mm, Shielding is not possible, solder, IP67
M16, series 723, Miniature connectors
Beställningsnummer |
99 0121 106 06
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0.75 mm² |
Tvärsnitt (AWG) | 20 |
Kabeluttag | 4,0 - 6,0 mm |
Kapslingsklass | IP67 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 95 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 5 A |
Märkspänning | 250 V |
Märksstötsspänning | 1500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | CuZn (brass) |
Kontaktplätering | Ag (silver) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Kontakthusmaterial | PA |
Customs tariff number | 85369010 |
Weight (g) | 36.351 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Nedladdningar
Produktblad
CAD-filer
99 0121 118 06
M16 IP67 male angled connector, Contacts: 6 DIN, 4,0 - 6,0 mm, Shielding is not possible, solder, IP67
M16, series 723, Miniature connectors
Beställningsnummer |
99 0121 118 06
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0.75 mm² |
Tvärsnitt (AWG) | 20 |
Kabeluttag | 4,0 - 6,0 mm |
Kapslingsklass | IP67 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 95 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 5 A |
Märkspänning | 250 V |
Märksstötsspänning | 1500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | CuZn (brass) |
Kontaktplätering | Au (gold) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Kontakthusmaterial | PA |
Customs tariff number | 85369010 |
Weight (g) | 37.888 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Nedladdningar
Produktblad
CAD-filer
99 0125 106 07
M16 IP67 male angled connector, Contacts: 7, 4,0 - 6,0 mm, Shielding is not possible, solder, IP67
M16, series 723, Miniature connectors
Beställningsnummer |
99 0125 106 07
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0.75 mm² |
Tvärsnitt (AWG) | 20 |
Kabeluttag | 4,0 - 6,0 mm |
Kapslingsklass | IP67 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 95 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 5 A |
Märkspänning | 125 V |
Märksstötsspänning | 800 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | CuZn (brass) |
Kontaktplätering | Ag (silver) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Kontakthusmaterial | PA |
Customs tariff number | 85369010 |
Weight (g) | 38.157 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Nedladdningar
Produktblad
CAD-filer
99 0125 118 07
M16 IP67 male angled connector, Contacts: 7, 4,0 - 6,0 mm, Shielding is not possible, solder, IP67
M16, series 723, Miniature connectors
Beställningsnummer |
99 0125 118 07
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0.75 mm² |
Tvärsnitt (AWG) | 20 |
Kabeluttag | 4,0 - 6,0 mm |
Kapslingsklass | IP67 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 95 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 5 A |
Märkspänning | 125 V |
Märksstötsspänning | 800 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | CuZn (brass) |
Kontaktplätering | Au (gold) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Kontakthusmaterial | PA |
Customs tariff number | 85369010 |
Weight (g) | 38.157 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Nedladdningar
Produktblad
CAD-filer
99 0581 106 07
M16 IP67 male angled connector, Contacts: 7 DIN, 4,0 - 6,0 mm, Shielding is not possible, solder, IP67
M16, series 723, Miniature connectors
Beställningsnummer |
99 0581 106 07
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0.75 mm² |
Tvärsnitt (AWG) | 20 |
Kabeluttag | 4,0 - 6,0 mm |
Kapslingsklass | IP67 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 95 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 5 A |
Märkspänning | 60 V |
Märksstötsspänning | 500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | CuZn (brass) |
Kontaktplätering | Ag (silver) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Kontakthusmaterial | PA |
Customs tariff number | 85369010 |
Weight (g) | 38.125 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Nedladdningar
Produktblad
CAD-filer
99 0171 106 08
M16 IP67 male angled connector, Contacts: 8 DIN, 4,0 - 6,0 mm, Shielding is not possible, solder, IP67
M16, series 723, Miniature connectors
Beställningsnummer |
99 0171 106 08
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0.75 mm² |
Tvärsnitt (AWG) | 20 |
Kabeluttag | 4,0 - 6,0 mm |
Kapslingsklass | IP67 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 95 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 5 A |
Märkspänning | 60 V |
Märksstötsspänning | 500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | CuZn (brass) |
Kontaktplätering | Ag (silver) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Kontakthusmaterial | PA |
Customs tariff number | 85369010 |
Weight (g) | 38.352 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Nedladdningar
Produktblad
CAD-filer
99 0171 118 08
M16 IP67 male angled connector, Contacts: 8 DIN, 4,0 - 6,0 mm, Shielding is not possible, solder, IP67
M16, series 723, Miniature connectors
Beställningsnummer |
99 0171 118 08
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0.75 mm² |
Tvärsnitt (AWG) | 20 |
Kabeluttag | 4,0 - 6,0 mm |
Kapslingsklass | IP67 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 95 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 5 A |
Märkspänning | 60 V |
Märksstötsspänning | 500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | CuZn (brass) |
Kontaktplätering | Au (gold) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Kontakthusmaterial | PA |
Customs tariff number | 85369010 |
Weight (g) | 38.352 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Nedladdningar
Produktblad
CAD-filer
99 0129 106 12
M16 IP67 male angled connector, Contacts: 12, 4,0 - 6,0 mm, Shielding is not possible, solder, IP67
M16, series 723, Miniature connectors
Beställningsnummer |
99 0129 106 12
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0.25 mm² |
Tvärsnitt (AWG) | 24 |
Kabeluttag | 4,0 - 6,0 mm |
Kapslingsklass | IP67 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 95 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 3 A |
Märkspänning | 60 V |
Märksstötsspänning | 500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | CuZn (brass) |
Kontaktplätering | Au (gold) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Kontakthusmaterial | PA |
Customs tariff number | 85369010 |
Weight (g) | 37.595 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Nedladdningar
Produktblad
CAD-filer
99 0451 106 14
M16 IP67 male angled connector, Contacts: 14, 4,0 - 6,0 mm, Shielding is not possible, solder, IP67
M16, series 723, Miniature connectors
Beställningsnummer |
99 0451 106 14
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0.25 mm² |
Tvärsnitt (AWG) | 24 |
Kabeluttag | 4,0 - 6,0 mm |
Kapslingsklass | IP67 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 95 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 3 A |
Märkspänning | 60 V |
Märksstötsspänning | 500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | CuZn (brass) |
Kontaktplätering | Au (gold) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Kontakthusmaterial | PA |
Customs tariff number | 85369010 |
Weight (g) | 37.756 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Nedladdningar
Produktblad
CAD-filer
99 0505 106 16
M16 IP67 male angled connector, Contacts: 16, 4,0 - 6,0 mm, Shielding is not possible, solder, IP67
M16, series 723, Miniature connectors
Beställningsnummer |
99 0505 106 16
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0.25 mm² |
Tvärsnitt (AWG) | 24 |
Kabeluttag | 4,0 - 6,0 mm |
Kapslingsklass | IP67 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 95 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 3 A |
Märkspänning | 60 V |
Märksstötsspänning | 500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | CuZn (brass) |
Kontaktplätering | Au (gold) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Kontakthusmaterial | PA |
Customs tariff number | 85369010 |
Weight (g) | 37.965 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Nedladdningar
Produktblad
CAD-filer
99 0461 106 19
M16 IP67 male angled connector, Contacts: 19, 4,0 - 6,0 mm, Shielding is not possible, solder, IP67
M16, series 723, Miniature connectors
Beställningsnummer |
99 0461 106 19
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0.25 mm² |
Tvärsnitt (AWG) | 24 |
Kabeluttag | 4,0 - 6,0 mm |
Kapslingsklass | IP67 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 95 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 3 A |
Märkspänning | 60 V |
Märksstötsspänning | 500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | CuZn (brass) |
Kontaktplätering | Au (gold) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Kontakthusmaterial | PA |
Customs tariff number | 85369010 |
Weight (g) | 38.232 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Nedladdningar
Produktblad
99 0495 106 24
M16 IP67 male angled connector, Contacts: 24, 4,0 - 6,0 mm, Shielding is not possible, solder, IP67
M16, series 723, Miniature connectors
Beställningsnummer |
99 0495 106 24
|
Kontaktdonslåsning | bolted |
Anslutning | solder |
Tvärsnitt (mm) | 0.14 mm² |
Tvärsnitt (AWG) | 26 |
Kabeluttag | 4,0 - 6,0 mm |
Kapslingsklass | IP67 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 95 °C |
Lägre gränstemperatur | -40 °C |
Märkström (40°C) | 1 A |
Märkspänning | 60 V |
Märksstötsspänning | 500 V |
Föroreningsgrad | 1 |
Överspänningskategori | I |
Isolermaterialgrupp | III |
Resistans | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | CuZn (brass) |
Kontaktplätering | Au (gold) |
Kontaktkroppsmaterial | PBT (UL 94 V-0) |
Kontakthusmaterial | PA |
Customs tariff number | 85369010 |
Weight (g) | 37.69 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Nedladdningar
Produktblad
CAD-filer
Contact to customer service
Do you have any questions regarding our products or do you wish an individual offer?