Ordering no:
Cable plug connector injection-moulded cable
Cable plug connector injection-moulded cable, Serier 692/693
Available numbers of contacts
79 0231 20 04
RD24 cable connector, Contacts: 4, Shielding is not possible, moulded on cable, IP67, 4 x 1,5 mm²
RD, series 692, Power connectors
Beställningsnummer |
79 0231 20 04
|
Kontaktdonslåsning | bolted |
Anslutning | moulded on cable |
Tvärsnitt (mm) | 1,50 mm² |
Tvärsnitt (AWG) | 16 |
Kapslingsklass | IP67 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 80 °C |
Lägre gränstemperatur | -25 °C |
Märkström (40°C) | 16 A |
Märkspänning | 400 V |
Märksstötsspänning | 6000 V |
Föroreningsgrad | 3 |
Överspänningskategori | III |
Isolermaterialgrupp | III |
Resistans | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | CuZn (brass) |
Kontaktplätering | Ag (silver) |
Kontaktkroppsmaterial | PA 12 |
Kontakthusmaterial | PUR |
Cable data | |
Mantelmaterial | PVC black |
Isoleringsfläta | PVC sw 1, sw 2, sw 3, grün/gelb |
Trådkonstruktion | 28x0,25 mm |
Ledarmotstånd | - |
Fixerad böjningsradie kabel | 120 mm |
Rörlig böjningsradie kabel | 60 mm |
Customs tariff number | 85444290 |
Weight (g) | 269 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- The end user must take suitable safety measures to ensure that the connector cannot be disconnected accidentally.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Nedladdningar
Produktblad
CAD-filer
79 0235 20 07
RD24 cable connector, Contacts: 7, Shielding is not possible, moulded on cable, IP67, 7 x 1,5 mm²
RD, series 692, Power connectors
Beställningsnummer |
79 0235 20 07
|
Kontaktdonslåsning | bolted |
Anslutning | moulded on cable |
Tvärsnitt (mm) | 0,75 mm² |
Tvärsnitt (AWG) | 20 |
Kapslingsklass | IP67 |
Mekanisk livslängd | > 500 Mating cycles |
Övre gränstemperatur | 80 °C |
Lägre gränstemperatur | -25 °C |
Märkström (40°C) | 8 A |
Märkspänning | 250 V |
Märksstötsspänning | 4000 V |
Föroreningsgrad | 3 |
Överspänningskategori | III |
Isolermaterialgrupp | III |
Resistans | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Kontaktmaterial | CuZn (brass) |
Kontaktplätering | Ag (silver) |
Kontaktkroppsmaterial | PA 12 |
Kontakthusmaterial | PUR |
Cable data | |
Mantelmaterial | PVC black |
Isoleringsfläta | PVC sw 1, sw 2, sw 3, grün/gelb |
Trådkonstruktion | 28x0,25 mm |
Ledarmotstånd | - |
Fixerad böjningsradie kabel | 120 mm |
Rörlig böjningsradie kabel | 60 mm |
Customs tariff number | 85444290 |
Weight (g) | 307 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Nedladdningar
Produktblad
CAD-filer
Contact to customer service